150℃ LSHF Flame-Retardant Elastomer Irradiated Insulating Compound
150℃ LSHF Flame-Retardant Elastomer Irradiated Insulating Compound is primarily formulated with halogen-free, non-toxic elastomers as the base resin, compounded with various additives through mixing and extrusion pelletization. It exhibits excellent processability, physical-mechanical properties, electrical insulation performance, and outstanding flame retardancy. During combustion, it releases no halogen acids and is self-extinguishing upon flame removal, significantly reducing toxic corrosive gas emissions and smoke generation. Cables manufactured with this material develop a smooth, rounded, elastic surface with superior hand feel after irradiation cross-linking. It is primarily used in control cables, instrument cables, and meter connection cables.
150℃ LSHF Flame-Retardant Elastomer Irradiated Insulating Compound List
Model |
Unit |
156E |
Item |
/ |
Typical |
Density |
g/cm3 |
1.46 |
Tensile Strength |
MPa |
9.6 |
Elongation at Break |
% |
236 |
Air Oven Aging |
℃×h |
180×168 |
Tensile Strength Change Rate |
% |
-6 |
Elongation at Break Change Rate |
% |
-5 |
Hot Set (0.2MPa) |
℃×min |
250×15 |
Elongation under Load |
% |
35 |
Permanent Deformation after Cooling |
% |
0 |
Low-temperature Performance Test |
℃ |
-45 |
Ozone Resistance Test |
/ |
No cracking |
Volume Resistivity at 20°C |
Ω·cm |
6.3×1014 |
Dielectric Strength at 20°C |
kV/mm |
22 |
Oxygen Index |
% |
29 |
Cable Flame Retardancy |
/ |
DZ-1 |
Smoke Density: Smoke with flame (Dmy) |
/ |
36 |
Smoke without flame (Dmw) |
/ |
132 |
Halogen Acid Gas Content |
mg/g |
0 |
pH Value |
/ |
6.1 |
Conductivity |
μs/mm |
1.5 |
Toxicity Index |
/ |
1.8 |
Environmental Protection Requirements |
Level |
Conforms to EU RoHS Directive (2011/65/EU) and REACH Regulation (EC 1907/2006) Substances of Very High Concern (SVHC) provisions. |
150℃ LSHF Flame-Retardant Elastomer Irradiated Insulating Compound Application
150℃ LSHF Flame-Retardant Elastomer Irradiated Insulating Compound exhibits excellent processability, physical-mechanical properties, electrical insulation performance, and outstanding flame retardancy. It is mainly used in control cables, instrument cables, and meter connection cables.